(5) Acoustic (STC) Ceiling - C001,CFCRESAM,CTCRRES and FCAIB-36
Resilient Mounts
- Supporting members, timber or steel to be spaced at a maximum of 1200 mm centres.
- Locate the resilient mounts product no. C001 at maximum 600mm centres along supporting
members.
- Fasten using appropriate fasteners dependant on the weight of the plasterboard being used.
- Locate the furring channel product no. FC18 or FC28 in the resilient mounts C001
- Locate short lengths of furring channel FC18 or FC28 to support butt joins in second layer of ceiling
lining or as per board supplier's specification.
Furring Channel Acoustic Isolation Batten FCAIB-36 (Resilient channel):
Refer to Fig 70
- Supporting members, timber or steel to be spaced at a maximum of 1200 mm centres.
- Locate the furring channel acoustic isolation batten (Resilient Channel)
(Peer product code FCAIB-36) at maximum 600 mm centres at right angles to supporting
members.
- Fasten the furring channel acoustic isolation batten FCAIB-36 using appropriate fasteners
dependant on the weight of the plasterboard being used.
-
Provide butt joins as per board supplier's specification.
|
|